24/7 Mobile Service & Workshop

Contact the Team on

(07) 5571 6155


Friday, October 26, 2018

this blog has moved to https://www.mobilehosefixersgoldcoast.com.au/blog/ Warning turn of the PTO Power Take Off before driving away to avoid Catastrophic Pump Damage


One of the most common failures we come across after hydraulic hose bursting or being damaged is the hydraulic pump which is part of the PTO on mobile hydraulic machinery.

What is a PTO? Power Take Of (Unit) is a specially designed gearbox that bolts to a Truck's Gear Gearbox or Transmission. They are used to drive Hydraulic Gear or Piston Pumps and to provide Fluid power to Mobile or Truck Mounted Hydraulic Systems such as those found in:

  • Compactors, 
  • Mobile Cranes, 
  • Walking Floors, 
  • Tilt Trays, 
  • Tow Trucks, 
  • Tippers, 
  • Low Loaders, 
  • Container Loaders, 
  • Winches, 
  • Skip Bin Trucks and
  • Concrete Agitators.

Most PTO Systems are designed to be engaged and operated whilst the vehicle is stationary and running at low to medium low engine speeds.

Click here to talk to one of our team about a new or replacement PTO System

So what happens when you forget to switch off the PTO and decide to drive off to the next destination? Over speed, Cavitation, Heat, Noise = Massive Wear and or eventual Catastrophic Failure.

Another Failed Idler Gear removed from a Damaged gear pump out of a Skip Bin Truck, the owner of this truck was wondering why the hydraulic pump could not generate enough power to lift bins on and off the truck.
In the example below the PTO was driving a pump for a tipper application the driver may have heard the additional noise and should have felt a great reluctance for the transmission to change gears.

The Picture shows such a failure probably caused by a combination of over speed, cavitation,  heat and sometimes lack of lubrication because correct oil level has not being maintained.

In the picture below The PTO is on the Right and Gear Pump is on the left.
Cavitation is the rapid formation and violent collapse of vapor pockets in a flowing liquid caused by areas or regions of very low pressure (read vacuum). Cavitation can and will cause Structural and Errosive damage.

Damaged power take off  gearbox and Hydraulic Gear pump caused by over speed when driver forgot to disengage the PTO gear box from the main transmission. Gear pump input shaft has sheared off in PTO out put shaft when gear teeth broke off  prevented further rotation.  

Cavitation damage can also be found in other types of liquid pumps as well as boat propellers.

In this example, running the PTO at High Speed caused the pump to Cavitate, Over Heat and rapidly Wear and Errode and eventually caused a hardened tooth to break off one of the gears. Being a solid the broken tooth jammed the rest of the gear pump and caused the whole pump to almost instantly stop. Because the PTO was still engaged and driving the pump the input shaft of the pump then sheared off in the PTO's Output shaft.

A failure like this will also require that the whole hydraulic system including hoses, pipes, cylinders, tank and suction strainer be flushed cleaned and all hydraulic oil and filters be replaced.

To Buy Online

  • Replacement PTO Pumps, 
  • Suction & Return Filters, 
  • Flow Control Valves,
  • Pressure Test Kits
  • Hydraulic Hose  
  • Remote Control Systems, 
  • D.I.Y Medium Pressure Hydraulic Hose Fittings to 270 Bar (4000 PSI) 
  • Custom Made High Pressure Hose Assemblies. To 410 Bar (6,000 PSI)
  • Click Here


Friday, September 28, 2018

this blog has moved to- https://www.mobilehosefixersgoldcoast.com.au/blog/ Troubleshooting High Pressure Hydraulic Systems with an Affordable Flow & Pressure Test Kit

Hydraulic Flow Testing 
A few years ago we were asked by one of our clients  "Do you do Flow Testing?"
We said "not yet, but we will investigate and get back to you". 

We called our specialist hydraulics suppliers looking for a Hydraulic flow test kit and we were astounded at the prices of flow test kits.
Starting from Au $4400 and you still needed to supply your own hoses and adaptors to connect to the hydraulic circuit you wanted to test. So flow testing went on the back burner for a while.
Eventually with more and more clients requesting flow testing services we borrowed a flow tester from one of our trusted advisers, Charlie Gray.
Charlie had built his own from bits and pieces laying around his hydraulics workshop and had then mounted it all into an empty Bosch drill case.
The seed was planted and we then took Charlie's Idea a few steps further and designed and assembled our own flow test kit with the following capabilities. 
  • Measure Oil Flows up to 120 litres per minute or (32 gallons/Min).
  • Induce Pressures up to 350 Bar (5150 PSI) 
  • Measure Oil Tempetatures up to 110 Degrees Celsius.
  • The latest upgrade has been to take the basic Single Direction to Oil Flow design and make it Bi Directional Oil Flow Design. 
  • This upgrade takes all errors out of the connection and testing process as well as being able to test Bi Directional Pumps, closed loop systems as well as Motor and cylinder circuits without having to disconnect and reconnect.
  • This upgrade is awesome value for money at $530 and is well worth it for the additional flexibility and versatility it provides.   
Your affordable flow test kit will be Supplied with two 1.5 meter long  3/4" High Pressure Hoses  and a selection of 28 adaptors, this allows the user of this kit to virtually connect to any BSP, JIC or SAE Flanged equipment.

We have sold this Flow Test Kit (see picture below) all over Australia. 
Our Price as you see it Under AU $2000 inclusive of GST.

To purchase this flow test kit including Hoses & Heavy duty carry case please click here



An alternative to the flow test kit is a High Quality German made 600 Bar (8820 PSI) rated Digital Pressure Test Kit From STAUFF Germany. 


 To Purchase this STAUFF 0 to 600 Bar (0 - 8,820 PSI) Digital Pressure Test Kit or to see our full range of pressure gauges please click here.

Description
A flow test is the quickest and least invasive way to quickly check for internal leakage of a suspected component in a hydraulic circuit be it a valve, motor or pump.

A flow test can also be used to ascertain if the engine or motor powering the hydraulic system is in good condition and or even capable of powering the hydraulic system's requirements. 
Hydraulic pumps, directional control valves, relief valves and cylinders in a hydraulic circuit can be individually checked for internal leakage.

Principle of operation,
The flow test kit is added into the hydraulic circuit and is connected as close as possible before or after the suspected component.

Using a relatively easy process of recorded measurements, logic and simple elimination each component can be individually tested and results compared to the performance of the rest of the hydraulic circuit.

The process described below is used for testing a hydraulic pump. 
The flow test kit is installed as close as possible to the pump's pressure port.
The pump is started and allowed to free flow without load. Flow, and temperature are recorded at free flow.

The flow control valve is then slowly closed to induce a resistance to flow and any changes to flow, pressure and temperature are recorded (usually at 20 Bar or 250 PSI intervals) this test is usually carried out up to the pump's maximum manufacturers recommended pressure. 

Results are then compared to manufacturer's data to ascertain any loss in performance. 

As a rule: A hydraulic system will have anywhere from 20 to 500 PSI system back Pressure, so if for example a pump has a 300 PSI system pressure and flows 100 Litres Per Min, and then flows 75 liters per Minute at 210 bar or 3000 PSI Pressure (75% on original flow) it is considered  okay to leave pump in service. 

Follow us on Facebook to see more of what we do on a daily basis

Friday, August 24, 2018

Blog has moved to https://www.mobilehosefixersgoldcoast.com.au/blog/ Rotary Coupling Manifold E45 Bobcat Excavator Remove and Reseal

Mobile Hose Fixers & Hydraulics 
Removes, Reseals and Re Installs Rotary Manifold on Bobcat E45 Excavator in 7 hours.

Have you ever wondered how the high pressure hydraulic oil (at 270 Bar 4000 PSI) that operates most of functions on an excavator can reach the track drive motors and blade while at the same time the cab, operator, boom, dipper, and bucket and the rest of entire top assembly (including counter weight and engine) can continue to rotate in either direction? 

Answer = A Rotary Manifold, Rotary Coupling or Rotary Joint.

To see a great visual explanation on how these rotary couplings work check out this pretty interesting youtube video, for earth mover section skip to 1:15 seconds in.

Heavy equipment rotary coupling starting at 1:15 seconds  

What is a Rotary Manifold ?
Simply explained a rotary Manifold is a large diameter drilled and grooved shaft that rotates in a fixed high pressure cylinder. 

The cylinder barrel has ports drilled along its length and the shaft is specially drilled and grooved to distribute the high pressure oil through to the ports drilled in the cylinder barrel. 

Multiple special seals and O rings are used to isolate each of the individual grooves or sections machined into the shaft. It is very clever and at the same time to so incredibly simple. 

The Symptoms of a Bad Rotary Coupling 
These can Vary from simply annoying to weird  for example
  • Oil leaking on to the ground or into the belly of the machine
  • Strange track drive performance (some operators call it a Lazy Drive) pushing both drive levers fully forward and the machine does track straight and either veers to the left or right and you having to compensate with less power to the more powerful less Lazy Drive. 
  • Operating one function like the high speed and having the blade move up or down 
  • Having to constantly adjust the blade Up because it keeps creeping down.
All the symptoms above could be indications that the seals in the rotary coupling may have deteriorated or failed. 

There are a series of test that we can carry out to confirm that it is the seals in your machine's rotary coupling that have failed and it is not the track drive motors or cylinder seals on the blade that are the problem.  Contact us with the link below.      

Want us to trouble shoot your Excavator problem or for Bobcat Service Maintenance and Hydraulic Hose Repairs, please click here



Rotary coupling assembly removed from  machine  after disconnecting all hydraulic hoses and removing some adaptors and location bolts 




Grooved and sealed rotary shaft each grove represents a function in this example 8 grooves for 8 functions, for example, Left Track Motor Forward & Reverse Grooves 1 & 2 , Right Track Motor Forward & Reverse grooves 3 & 4 , Track Drives High Speed Mode groove 5, Track Motors Case Drain groove 6,  Blade Up & Down grooves 7 & 8 . 

Total time including draining hydraulic oil tank disconnecting and reconnecting all hoses and testing, 7 hours. (please not rotary coupling seals need to be ordered in advance of job commencing)

Follow us on Facebook to watch our latest adventures and challenges in Hydraulics

Wednesday, October 21, 2015

Prototype Custom Built Harvester attachment built and tested in 3 weeks.

We recently had the pleasure of working with a bunch of talented guys on a Prototype Harvester for an International Client.
Because of Intellectual Property we can't say much about what the prototype harvests and how it works.
Other than the prototype uses electronically controlled Hydraulic Sectional Valve to move Hydraulic Cylinders that adjust shutes, compactors and cutter angles and Hydraulic motors to operate a series of mechanical cutters and Rotate blowers.
The great win on this project was that, what is pictured below was Fabricated, Painted, Hosed, Wired up and Tested all in 3 weeks.
It was great to work with a team of people right here on the Gold Coast with many backgrounds, specialties and skills who just dug in a got the Job done, very nice working with you Gents.






Friday, August 28, 2015

Win a Mini Bar Fridge Full of Beer or Energy Drink of your Choice


MHF New Logo jpg.jpg AusT Made black and white small .jpg

Win a Mini Bar Fridge FULL with Your choice of BEER* or Energy Drink.


GLASS DOOR MINI BAR FRIDGE - 52 LITRES
- COOL CURVED DOOR- LED DISPLAY
  • Double glazed.
  • Reversible door with lock.
  • Manual temperature control with Blue LED temperature display.
  • Dimensions: W: 435mm x D: 520mm x H: 510mm.
  • Internal Dimensions: W: 380mm x D: 380mm x H: 410mm.
  • Compressor driven with R134A refrigerant, 45g.
  • Shelf positions are 140mm, 195mm, 280mm, 335mm from floor.
  • Holds 38 x stubbies and/or cans.
  • Weight: 20kg.
  • Input Power: 80 Watt.
  • Power Consumption: 0.8Kwh/24hr.
  • Warranty: 12 months parts and labour.
  • Australian MEPS compliance approved.

For every Job or Legitimate* referral you give us, you get One chance to Win. Call Now 0n
07 5571 6155 or E-mail your order / referral to sales@mhfgc.com.au or TEXT to 0431 022 452.

Dates from Sat 29 Aug 2015 to Wed 30 Sep 2015. * Conditions Apply
For more info please visit, http://www.mhfgc.com.au/index.php/news


Sunday, August 9, 2015

Lost a Customer or Client Recently? Reasons They Left & Where they Went!

If you have recently Lost a Customer or Client, what do you think is the most common answer to the reasons they left & went elsewhere!

Of the 5 categories below take a guess as a % what the true answers are.
  1. Have a relationship at a High level Customers had a close relationship with one of your employees who moved to another company or started their own business. Your guess _ _ %?
  2. Convenience Means a person chose not to deal with your business and instead went elsewhere because it was more convenient to purchase there. Your Guess _ _ %?
  3. Miscellaneous A number of random reasons that can not be categorised. Your Guess _ _ %?
  4. Product, Time, Price, Means a potential customer wanted a certain product or service at a certain time and or at a certain place whenever that may have been (now or in the future) and you were not able to accommodate them no matter what the price was. Your guess _ _ %?
  5. _ _ _ _ _ _ _ _ _ _ _? Take a guess at what best represents the missing reason that customers chose not to buy and leave a business. Your guess _ _ %?
While you are pondering an answer to Category 5, read the following 3 points, they may help you to generate a reason.
  • Only 4% of unhappy customers will actually speak up and tell you why they are unhappy, the remaining 96% will keep their mouth shut and just leave, however 91% will never come back!
  • An unhappy or disappointed customer will on average tell 10 other people how you, your company and or employees disappointed them. One in 5 of those disappointed customers will tell more than 20 people!
  • A customer who has had a great and or satisfying experience with you, your employees and or your company will tell on average another 5 people.  
Answers 
No 1, Have a relationship at a high level = 4%,
No 2, Convenience = 9%,
No 3, Miscellaneous = 5%,
No 4, Product, Time, Price, = 14%, 

No 5, = Perceived Indifference = 68% This means 68% of customers felt that you and or your employees did not really care enough about them and whether they purchased from you or not. Additionally you and or your team failed to regularly contact them and or to provide them with personal individual attention. 68%! 
So how do you improve on your perceived indifference in the eyes of your current and potential new customers?

Ask yourself and your employees to answer the following questions.

  • Do you answer the phone between 3 -6 rings every time?
  • Does every caller get asked for permission before they are put on hold?
  • Do you make sure no one is on hold for more than 30 seconds?
  • Do you have an on hold message to listen to?
  • Do you thank your customers or potential customers for calling?
  • Do you greet your clients the moment you see them walk through the door? even when you are busy and or on the phone.
  • Do you thank your customers or potential customers for visiting your business?
  • Do you thank your customers for purchasing from you?
  • Do you and your employees always arrive on time for meetings with customers.
  • Do you deliver products and services when you say you will every time?
  • Do you always let your customers know before hand if there is a problem?
  • Do you always return phone calls the same day you get the message?
  • Does each of your employees take responsibility for helping customers or do they hand off customer problems to one another or from department to department?
  • Do you always ask for more information when you are asked about the price of a product or service?
  • Do you always follow up on your customers in the days or weeks after they have purchased a product or service of you to make sure that they are happy?
  • Do you stay in touch with your customers regularly?
  • Do you ever surprise them by giving them a small gift?
  • Do you keep them informed about new things happening in your business?
  • Do you thank your internal customers your employees for being part of your business?

And Finally the "Net Promoter Score" this is one simple question asked by many large and successful corporations. 
They ask their customers the following simple question,
"On a scale of 1 to 10 with 1 being least likely and 10 being most likely, How likely is it that you would recommend our company to a colleague, relative or another business?"   
The goal is an average score of 8 or above. A score of 7 or less is considered not good enough and warrants further investigation and improvement . 

Please feel free to post comments and share with us your wins or fails.

Tuesday, June 2, 2015

140 Ton Custom Built Hitachi Demolition Excavator ("the Big Girl") Devours a 10 Storey Hospital building in 6 months!

Over the past few months we have had the pleasure to apply our Mobile HoseFixing services to some of the largest demolition equipment ever seen on the Gold Coast.
It started with us fixing rotation hoses, muncher hoses and pulveriser hoses on a 60 ton Komatsu and then on a 70 ton Hitachi long arm. Muncher hoses for the 70 ton were 1" inside diameter had to be rated from 4000 and 5000  PSI working pressure.

After a couple of months we heard rumors that " a Big Girl" was on her way to site.  And arrive she did. The Big Girl took 2 weeks to assemble and once complete weighed in at 140 metric tons.

The Big Girl was built in Japan by Hitachi as an excavator and then shipped to England for special modifications to convert her to demolition duties. Australia has very strict rules when it comes to demolition,  so the fancy and speedy collapsing of a building in a cloud of dust and airborne particles by detonating explosives is pretty rare these days.

The Big Girl is equipped with Extra wide tracks, a 3 stage telescopic boom, 4 hydraulic Pumps generating pressures between 200 and 340 Bar (3000 and 5000 PSI) and a 800 liter hydraulic oil tank.
She does not swing a wrecking ball or use her huge mass to push or crush a building but rather she uses specialised attachments to bite, pulverise, munch and persistently gnaw the building down to the ground.
These special attachments require very high hydraulic pressures to operate effectively and we have had to assemble hoses, fittings and valves rated to 400 Bar (6000 PSI). Hoses designed to operate at these pressures can be reinforced with up to 6 layers of spirally wound high tensile steel wire.


Repairs and Maintenance on the Big Girl Elevated Work Platform Required.